OXYGEN HEADSPACE & CO2 ANALYZERS

MORE

Used for the measurement of residual oxygen in food packages.
The expected oxygen sensor life is typically 5 years, unlike other analyzers with a
sensor that last 1-2 years,
reducing total cost of ownership, and analyzer downtime.

 

quantek-headspace-oxygen-analyzer-901.jpg

 

 

Save

Save

Save

  • Technical Specifications – Oxygen Channel

    Oxygen  Sensor Type:  Proprietary Electrochemical
    Expected Lifetime:  4-5 years
    Oxygen  Range: 0 to 100%
    Oxygen  Sensitivity: 0.1% O2
    Oxygen  Minimum Detection Limit: 0.1% O2
    Oxygen Calibration Controls:  SPAN adjustment, zero adjustment
    O2 Calibration Frequency:  Weekly; set with room air set to 20.9% O2.
    O2 Resolution:  0.1% O2  (optional .01%)

Technical Specifications – Carbon Dioxide Channel

    Carbon Dioxide Sensor Type:  Solid-state Infrared
    Expected Lifetime:  Theoretically unlimited
    Measurement Ranges:  0-20%  or 0-100%
    Accuracy (for 0-100% range):     ± 1% of reading, or ± 0.2% CO2 
    (whichever is greater)
    Accuracy (for 0-20% range):     ± 1% of reading or ± 0.1% CO2 
    (whichever is greater)
    
CO2 Minimum Detection Limit:  0.1%  (0-100% range)
CO2 Minimum Detection Limit:  0.01%  (0-0-20% range)
CO2 Calibration Controls:  Potentiometer SPAN adjustment for CO2.
CO2 Calibration Frequency:  Every 18 months; calibration gas recommended.

Technical Specifications - All

    Sample Pump - Miniature diaphragm type with ~5cc/sec flow
    Pump Timing – 2-12 second adjustable pump time, 
                                    potentiometer on back of analyzer
    Sampling Port - Double reinforced sample probe (~12in. length)
    Exhaust port – Vents to air
    Size -  9.8W x 4H x 10L in. (249 x 102 x 254 mm)
    Weight - 9.8 lb. (4.4 Kg)
    Warranty - 2 years, parts and labor
    Standards - CE, RoHS,
    Origin of Goods -   Manufactured in the U.S.A. Technical Specifications – Oxygen Channel

    Oxygen  Sensor Type:  Proprietary Electrochemical
    Expected Lifetime:  4-5 years
    Oxygen  Range: 0 to 100%
    Oxygen  Sensitivity: 0.1% O2
    Oxygen  Minimum Detection Limit: 0.1% O2
    Oxygen Calibration Controls:  SPAN adjustment, zero adjustment
    O2 Calibration Frequency:  Weekly; set with room air set to 20.9% O2.
    O2 Resolution:  0.1% O2  (optional .01%)

Technical Specifications – Carbon Dioxide Channel

    Carbon Dioxide Sensor Type:  Solid-state Infrared
    Expected Lifetime:  Theoretically unlimited
    Measurement Ranges:  0-20%  or 0-100%
    Accuracy (for 0-100% range):     ± 1% of reading, or ± 0.2% CO2 
    (whichever is greater)
    Accuracy (for 0-20% range):     ± 1% of reading or ± 0.1% CO2 
    (whichever is greater)
    
CO2 Minimum Detection Limit:  0.1%  (0-100% range)
CO2 Minimum Detection Limit:  0.01%  (0-0-20% range)
CO2 Calibration Controls:  Potentiometer SPAN adjustment for CO2.
CO2 Calibration Frequency:  Every 18 months; calibration gas recommended.

Technical Specifications - All

    Sample Pump - Miniature diaphragm type with ~5cc/sec flow
    Pump Timing – 2-12 second adjustable pump time, 
                                    potentiometer on back of analyzer
    Sampling Port - Double reinforced sample probe (~12in. length)
    Exhaust port – Vents to air
    Size -  9.8W x 4H x 10L in. (249 x 102 x 254 mm)
    Weight - 9.8 lb. (4.4 Kg)
    Warranty - 2 years, parts and labor
    Standards - CE, RoHS,
    Origin of Goods -   Manufactured in the U.S.A.

    902D OXYGEN ANALYZER

    SALES (804) 435-5522 902D O2 / CO2 Dual Track ANALYZER For Analysis of Oxygen and Carbon Dioxide in Gas Flushed (MAP) Food Packages BROCHURE QUICK QUOTE Includes everything you need to begin sampling:   Built-in pump, sample probe. Starter...

    $3,100.00
    Add to Cart